Dynamic UPS range

Dynamic UPS: dynamic Uninterruptible Power Supplies

The Active Power dynamic UPS come in the form of a compact unit that can easily be installed in the vicinity of your sensitive equipment.

Find out more about our product range

Active Power SMS (Single Module System) UPS – 333 kVA

CS+ 300 SMS 333kVA-300kW
Key features of the UPS:
  • Energy storage through kinetic flywheel
  • Battery-free single module system (space requirements reduced by 1.4 m²/333 kVA)
  • No air conditioning required for installation (temperature range from 0 to 40 °C)
  • I/O voltage 400 V
  • Yield 98%
  • Cos φ = 0.9 (333 kVA-300 kW)
  • Analogue, SNMP and Modbus communication interfaces
  • Parallelable x 8
  • Eliminates all micro-power cuts
  • Charging power during genset start-up
  • Eliminates all power over- or under-loads
  • Filters upstream and downstream harmonics
  • Regulates voltage
  • Power factor regulator (Cosø)
  • Progressive load transfer
  • 2nd power source for genset starter

Active Power MMS inverter (Multi Module System) – 333 – 2666 kVA

CS+ 300 MMS Series 333kVA-300kW/1333kVA-1200kW
Key features of the UPS:
  • Models available CS+300(333kVA/300kW), CS+300 N+1(333kVA/300kW), CS+600(666kVA/600kW), CS+600 N+1(666kVA/600kW), CS+900(1,000kVA/900kW), CS+900 N+1(1,000kVA/900kW), CS+1200(1,332kVA/1,200kW)
  • Energy storage through kinetic flywheel
  • Mutli-module battery-free system
  • No air conditioning required for installation (temperature range from 0 to 40 °C)
  • I/O voltage 400 V
  • Yield 98%
  • Cos φ = 0.9 (e.g. 333 kVA-300 kW)
  • Analogue, SNMP and Modbus communication interfaces
  • Parallelable with max. 8 flywheels in parallel
  • Eliminates all micro-power cuts
  • Charging power during genset start-up
  • Eliminates all power over- or under-loads
  • Filters upstream and downstream harmonics
  • Regulates voltage
  • Power factor regulator (Cosø)
  • Progressive load transfer
  • 2nd power source for genset starter

Active Power SMS (Single Module System) UPS – 625 kVA

CSHD SMS Series 625kVA-625kW
Key features of the UPS:
  • Energy storage through kinetic flywheel
  • Battery-free single module system (space requirements reduced by 1.4 m²/333 kVA)
  • No air conditioning required for installation (temperature range from 0 to 40 °C)
  • I/O voltage 400 V
  • Yield 98%
  • Cos φ = 0.9 (333 kVA-300 kW)
  • Analogue, SNMP and Modbus communication interfaces
  • Parallelable x 8
  • Eliminates all micro-power cuts
  • Charging power during genset start-up
  • Eliminates all power over- or under-loads
  • Filters upstream and downstream harmonics
  • Regulates voltage.
  • Power factor regulator (Cosø)
  • Progressive load transfer.
  • 2nd power source for genset starter

Critical Power Module (CPM)

CS+ 300 MMS Series 333kVA-300kW/1333kVA-1200kW
Key features of the CPM
  • Range: 333-666-1,000-1,332 kVA
  • ISO container 20 feet (333 kVA) or 40 feet (660-1332 kVA) fitted as standard with:
    • A dynamic UPS
    • A CATERPILLAR genset
  • Plug-and-play solution that meets the growing demand for modularity and flexibility
  • The combination of a dynamic UPS and a genset provides optimal “time zero” type protection for your electricity supply (no outages)
  • The container is adapted in line with the specific acoustic, integration and inverter requirements, etc.

Thanks to its expertise, Eneria is able to adapt the CPM configuration to align with your needs. For more information, please contact us.

How dynamic UPS work

Dynamic UPS are based on the Active Power online parallel architecture, which provides excellent insulation between the input and the output, plus class 1 voltage regulation and the dynamic elimination of the effects of non-linear load harmonics. This topology permanently protects the online power supply in your data centre, by creating a specific sinusoidal outlet wave form and by protecting critical loads against the nine forms of interference with power supplies defined by the IEEE, in a high-power, reliable and energy-efficient unit.

Dynamic UPS are usually coupled to a genset. The combination of a dynamic UPS and a genset provides optimal “time zero” type protection for your electricity supply.

Critical Power Modules (CPM)

Eneria also offers the Critical Power Module (CPM) to optimise your projects. Developed as a solution in a standard ISO container, the CPM is a highly efficient module that can deliver an uninterruptible power supply to critical consumers, from 333 kVA to 1,333 kVA per module.

It consists of a CATERPILLAR genset and an ACTIVE POWER dynamic UPS, housed in a standard 20 or 40-foot ISO container adapted to the customer’s needs.

The CPM is a true plug-and-play concept that meets the growing demand for modularity and flexibility.